Skip to content

Mosa GE 10 YSXC Diesel Generating Set - Stage 5 YANMAR Engine

by MOSA
SKU 35.CE3Q1012
Original price £9,307.20 - Original price £9,307.20
Original price
£9,307.20
£9,307.20 - £9,307.20
Current price £9,307.20
Unsure? Get in touch...

We are always happy to help. If you have any questions or can't find what you are looking for just give us a call on 01375 800761 or email us at sales@toolweld.co.uk

Get an Additional Discount!

Simply use the code WELD5 at the checkout to get even more savings when you spend £250 or more...

GE 10 YSXC

Generator Diesel YANMAR 3TNV80 - Three-phase synchronous alternator - Water Cooled

POWER RATINGS

  • Stand-By three-phase power: 9.5 kVA (7.6 kW) / 400V / 13.7A
  • PRP three-phase power: 9 kVA (7.2 kW) /400V / 13A
  • PRP single-phase power: 4.5 kVA / 230V / 19.5A
  • Frequency: 50 Hz
GENERAL SPECIFICATIONS

  • Fuel tank capacity: 30 lt.
  • Running time (75% to PRP): 15 h
  • Measured acoustic power LwA (pressure LpA): 87 dB(A) (62 dB(A) @ 7 m)
  • Guaranteed acoustic power LwA (pressure LpA): 88 dB(A) (63 dB(A) @ 7 m)
  • Dry Weight: 410 kg
  • Dimensions (LxWxH): 1460x700x920 mm
Model Fuel Starter Output Stand By Output PRP Cylinders / Displacement Speed Cooled
YANMAR 3TNV80 Diesel Electric 9 kW (12.2 HP) 8.2 kW (11.1 HP) 3 / 1267 cm³ 1500 rpm

Water

 

COMPOUND + AVR

Double Control- Security of Supply: With this system both AVR and Compound control systems are normally active. When a heavy load current is required (example - motor starting) the compound regulation overrides the AVR thereby ensuring high availability of required current. In standard operating conditions the AVR regulation prevails, which ensures high quality, precise control of the AC output.

In case of AVR failure, the Compound regulation maintains voltage regulation, albeit with reduced control characteristics.